Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
BMC Med Educ ; 22(1): 579, 2022 Jul 28.
Article in English | MEDLINE | ID: mdl-35902953

ABSTRACT

BACKGROUND: The use of head mounted display (HMD)-based immersive virtual reality (VR) coaching systems (HMD-VRC) is expected to be effective for skill acquisition in radiography. The usefulness of HMD-VRC has been reported in many previous studies. However, previous studies have evaluated the effectiveness of HMD-VRC only through questionnaires. HMD-VRC has difficulties in palpation and patient interaction compared to real-world training. It is expected that these issues will have an impact on proficiency. The purpose of this study is to determine the impact of VR constraints in HMD-VRC, especially palpation and patient interaction, on radiographic skills proficiency in a real-world setting. METHODS: First-year students (n = 30) at a training school for radiology technologists in Japan were randomly divided into two groups, one using HMD-VRC (HMD-VRC group) and the other practicing with conventional physical equipment (RP group) and trained for approximately one hour. The teachers then evaluated the students for proficiency using a rubric method. RESULTS: In this study, it was found that some skills in the HMD-VRC group were equivalent to those of the RP group and some were significantly lower than those of the RP group. There was a significant decrease in proficiency in skills related to palpation and patient interaction. CONCLUSIONS: This study suggests that HMD-VRC can be less effective than real-world training in radiographic techniques, which require palpation and patient interaction. For effective training, it is important to objectively evaluate proficiency in the real world, even for HMD-VRC with new technologies, such as haptic presentation and VR patient interaction. TRIAL REGISTRATION: The study was conducted with the approval of the Ethics Committee of International University of Health and Welfare (Approval No.21-Im-035, Registration date: September 28, 2021).


Subject(s)
Radiography , Radiology , Virtual Reality , Educational Measurement/methods , Humans , Radiology/education , Smart Glasses
2.
Ann Nucl Med ; 34(11): 799-806, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32852747

ABSTRACT

The diagnostic reference levels (DRLs) are one of several effective tools for optimizing nuclear medicine examinations and reducing patient exposure. With the advances in imaging technology and alterations of examination protocols, the DRLs must be reviewed periodically. The first DRLs in Japan were established in 2015, and since 5 years have passed, it is time to review and revise the DRLs. We conducted a survey to investigate the administered activities of radiopharmaceuticals and the radiation doses of computed tomography (CT) in hybrid CT accompanied by single photon emission computed tomography (SPECT)/CT and positron emission tomography (PET)/CT. We distributed a Web-based survey to 915 nuclear medicine facilities throughout Japan and survey responses were provided by 256 nuclear medicine facilities (response rate 28%). We asked for the facility's median actual administered activity and median radiation dose of hybrid CT when SPECT/CT or PET/CT was performed for patients with standard habitus in the standard protocol of the facility for each nuclear medicine examination. We determined the new DRLs based on the 75th percentile referring to the 2015 DRLs, drug package inserts, and updated guidelines. The 2020 DRLs are almost the same as the 2015 DRLs, but for the relatively long-lived radionuclides, the DRLs are set low due to the changes in the Japanese delivery system. There are no items set higher than the previous values. Although the DRLs determined this time are roughly equivalent to the DRLs used in the US, overall they tend to be higher than the European DRLs. The DRLs of the radiation dose of CT in hybrid CT vary widely depending on each imaging site and the purpose of the examination.


Subject(s)
Diagnostic Imaging/standards , Nuclear Medicine/standards , Humans , Japan , Reference Standards , Surveys and Questionnaires
3.
J Am Coll Cardiol ; 49(13): 1436-42, 2007 Apr 03.
Article in English | MEDLINE | ID: mdl-17397672

ABSTRACT

OBJECTIVES: The aim of this study was to investigate the prevalence and severity of left atrial (LA) edema after pulmonary vein (PV) ablation and its effect on the cardiac function. BACKGROUND: Though extensive LA catheter ablation has been demonstrated to be more effective in curing paroxysmal atrial fibrillation (PAF) than segmental ostial pulmonary vein isolation (S-PVI), it might cause life-threatening complications, including congestive heart failure associated with LA edema. METHODS: Fifty patients underwent S-PVI (Group S) and 27 underwent circumferential PV antrum ablation (Group C) for drug-refractory PAF. Enhanced electron beam tomography (EBT) was performed before, 1 or 2 days after, and 1 month after the PV ablation, and transthoracic ultrasound cardiography (UCG) was performed 1 month after the PV ablation in all patients. RESULTS: The EBT assessment revealed LA edema immediately after the PV ablation in 47 Group S patients and all Group C patients. The severity of the LA edema, number of radiofrequency applications, and amount of radiofrequency energy delivered during the PV ablation was significantly greater in Group C than in Group S. One month after the PV ablation, in all patients, the EBT assessment revealed that those edematous changes had disappeared, and the UCG assessment showed no reduction in the cardiac function. CONCLUSIONS: Left atrial edema was observed in a large portion of the patients immediately after the PV ablation, and the severity of the LA edema depended on the extent and amount of the radiofrequency energy delivered in the PV ablation. The LA edema soon disappeared naturally and did not reduce the cardiac function.


Subject(s)
Catheter Ablation , Edema, Cardiac/diagnosis , Edema, Cardiac/epidemiology , Heart Atria , Pulmonary Veins/surgery , Tomography, X-Ray Computed , Atrial Fibrillation/surgery , Edema, Cardiac/diagnostic imaging , Female , Humans , Male , Middle Aged , Prevalence , Severity of Illness Index , Time Factors , Ultrasonography
4.
J Electrocardiol ; 40(4): 319-25, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17276446

ABSTRACT

BACKGROUND: This study investigated the electrophysiologic characteristics and outcome of superior vena cava (SVC) segmental ostial isolation (SOI) in patients with SVC-initiated paroxysmal atrial fibrillation (PAF). METHODS: Ninety-five patients with PAF underwent pulmonary vein (PV) SOI using a basket catheter whether the PAF originating from PVs was observed or not. Fifteen of those patients also underwent SVC SOI in the same manner due to evidence of SVC origin PAF. RESULTS: The SVC musculature networks and electrical connections with the atrium (multiple separate electrical connections in 10, multiple separate musculature networks with separate electrical connections in 1, and a continuous broad electrical connection in 4 SVCs) were similar to those of the PV musculature. However, the occurrence of an electrical connection recovery after SOI in patients with recurrent atrial fibrillation was lower for SVCs (25%) than PVs (58%). CONCLUSIONS: Superior vena cava SOI appears to have a lower recurrent conduction rate than PV SOI.


Subject(s)
Atrial Fibrillation/surgery , Heart Conduction System/surgery , Pulmonary Veins/surgery , Superior Vena Cava Syndrome/surgery , Ventricular Premature Complexes/surgery , Adult , Atrial Fibrillation/diagnosis , Body Surface Potential Mapping , Female , Humans , Male , Treatment Outcome , Ventricular Premature Complexes/diagnosis
5.
Radiat Med ; 24(10): 675-9, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17186322

ABSTRACT

PURPOSE: We investigated the difference between measured and manufacturer's nominal source strength in a large sample of a single model of (125)I seeds. Physical characteristics of single seed measurement by the well-type ionization chamber were also investigated to provide dosimetric data. MATERIALS AND METHODS: A well-type ionization chamber with a single seed holder was used to measure source strength of all 1935 (125)I seeds implanted in the initial 28 patients in our hospital. Physical characteristics including linearity of readings for different integral time intervals, reproducibility, isotropy, and axial positional sensitivity were assessed. To calculate the source strength, the integral charge during 30 s was measured and converted to air kerma strength. The nominal activity stated by the manufacturer was compared with the measured value. RESULTS: Linearity, reproducibility, and isotropy of the well-type ionization chamber were within 0.2%. Measured source strength was on average 2.1% (range -7.6% to +7.2%), lower than the nominal value. Standard deviation of all measured seeds was 2.0%. The maximum difference between the measured and the manufacturer's nominal source strength in each patient was -3.7%. The standard deviation averaged 1.6%. CONCLUSION: The nominal source strength of the (125)I seeds agreed well with the measured value. Our study can be helpful as guidance for individual (125)I seed source strength measurement.


Subject(s)
Brachytherapy/methods , Iodine Radioisotopes/administration & dosage , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Humans , Male , Radiotherapy Dosage
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 62(12): 1690-6, 2006 Dec 20.
Article in Japanese | MEDLINE | ID: mdl-17189936

ABSTRACT

We proposed a formula for the enhanced dynamic wedge (EDW) factor in the half-field (HF) that combined the formula proposed by Liu et al. in 1998 and their formula in 2003. When the EDW was used for irradiation to the tangent line of the HF breast, the values calculated by our formula and the measured values were consistent within 0.5%. We showed that our proposed formula was useful, easy to use, and more accurate than the conventional formula. The purpose of this study was to examine the available range of the wedge factor of symmetrical and asymmetric EDW calculated by our formula. As a result of the examination, the values calculated by our formula and the measured values were consistent within 2% except for highly asymmetric EDW. We created a spreadsheet to calculate the wedge factor easily and accurately. We will examine the reason why the calculated and measured values were greater than 2%, and improve our formula so that it can be used in a wider range.


Subject(s)
Radiometry/methods , Radiotherapy Dosage , Radiotherapy, Computer-Assisted/methods , Calibration , Humans
7.
Am J Cardiol ; 97(12): 1741-4, 2006 Jun 15.
Article in English | MEDLINE | ID: mdl-16765125

ABSTRACT

It has been reported that plasma atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) levels are elevated in patients with atrial fibrillation (AF). The aim of this study was to investigate the change in these patients after pulmonary vein isolation (PVI). In 66 patients with paroxysmal AF (PAF) and without any structural heart disease, plasma ANP and BNP levels were measured before and 3 months after successful PVI. At baseline, in 14 patients, ANP and BNP levels were elevated, and in 52 patients, only BNP levels were elevated. There were no significant relations between the attack frequency or the duration of PAF episodes and ANP or BNP levels. Neither ANP nor BNP level at baseline was a valid predictor of AF recurrence. Even in 31 patients (47%) with recurrent PAF, attacks of PAF were significantly reduced. In 66 patients with elevated ANP and/or BNP levels at baseline, levels were significantly reduced after PVI independent of PAF recurrence (ANP: 69.0+/-23.0 vs 25.0+/-7.7 pg/ml, p<0.0001; BNP: 58.4+/-50.7 vs 22.5+/-27.1 pg/ml, p<0.0001). In 42 patients without AF recurrences, ANP and BNP levels were reduced to within the normal range. In conclusion, in patients with PAF without any structural heart disease, ANP and/or BNP levels were elevated. In those patients, relief of the AF burden by successful PVI significantly reduced elevated plasma ANP and BNP levels.


Subject(s)
Atrial Fibrillation/blood , Atrial Fibrillation/surgery , Atrial Natriuretic Factor/blood , Catheter Ablation , Natriuretic Peptide, Brain/blood , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Retreatment
8.
Am J Cardiol ; 97(10): 1494-7, 2006 May 15.
Article in English | MEDLINE | ID: mdl-16679091

ABSTRACT

To avoid fatal complications after extensive pulmonary vein (PV) ablation, it has been proved important to comprehend the anatomic relation between the PVs and the esophagus. In 42 consecutive patients with atrial fibrillation, PV ostial isolation was performed using a basket catheter. The shortest distance and anatomic relation between the esophageal lead and PV ostium, determined by successful PV ostial isolation, was analyzed in biplane fluoroscopic views. In 18 left superior PVs (LSPVs) (43%), 13 left inferior PVs (32%) (LIPVs), and all the right PVs (group A), the shortest distance was > 10 mm in > or = 1 of the biplane fluoroscopic views. In 4 LSPVs (10%) and 2 LIPVs (5%) (group B), the shortest distance was < or = 5 mm in the fluoroscopic views. In the remaining PVs (group C), the esophagus was situated directly behind 10 LSPVs (24%) and 12 LIPVs (29%) (group C1), posteromedial to 1 LSPV (2%) and 9 LIPVs (22%) (group C2), and medial to 9 LSPVs (21%) and 5 LIPVs (12%) (group C3). The risk of esophagus-associated complications with ablation around the left PV ostia was suggested to be high in group B, very low in group A, and relatively low in group C. In group C3, extensive PV ablation might increase the risk of that complication. In conclusion, esophageal leads are useful for determining strategies for PV ablation to avoid esophagus-associated complications, because they enable comprehension of the anatomic relation between the PVs and the esophagus.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Esophagus/anatomy & histology , Pulmonary Veins/anatomy & histology , Pulmonary Veins/surgery , Chi-Square Distribution , Female , Fluoroscopy , Humans , Male , Middle Aged , Postoperative Complications/prevention & control , Retrospective Studies , Treatment Outcome
9.
Europace ; 8(3): 182-8, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16627436

ABSTRACT

AIMS: The aim of this study was to reveal the incidence, location, and cause of recovery of the electrical connections (ECs) between the left atrium and the pulmonary veins (PVs) after the segmental ostial PV isolation (PVI). METHODS AND RESULTS: Pulmonary vein mapping and successful PVI were performed using a computerized three-dimensional mapping system (QMS2trade mark) with a basket catheter in 167 PVs in 53 consecutive patients with atrial fibrillation (AF). In 14 patients with recurrent AF after PVI, the same PV mapping and isolation as in the first procedure were performed, and the PV potential maps constructed by QMS2 in two different procedures were compared. Forty-nine recovered ECs were observed in 27 PVs, and all were eliminated by a few local radiofrequency (RF) applications. Thirty-four (69%) of those ECs recovered at the edge of original ECs, and another 15 (31%) recovered at the mid-portion of the continuous broad original ECs. CONCLUSION: Electrical connection recovery occurred most commonly at the edges of original ECs and occasionally at the mid-portion of continuous broad original ECs after PVI probably due to tissue oedema neighbouring the segmental RF lesions. Further RF lesions at the edge of original ECs and linear ablation to the continuous broad ECs may help reduce AF recurrence.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Heart Atria , Heart Conduction System/surgery , Pulmonary Veins , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Heart Conduction System/physiopathology , Humans , Male , Middle Aged , Retreatment
10.
Int Heart J ; 47(2): 219-28, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16607049

ABSTRACT

The aim of this study was to investigate whether segmental ostial catheter ablation (SOCA) designed to prevent the electrical connections (ECs) between the left atrium and pulmonary veins (PVs) might help increase the efficacy of SOCA in paroxysmal atrial fibrillation (PAF). PV mapping and successful SOCA were performed with a basket catheter in 108 consecutive patients with PAF. Radiofrequency energy was delivered using a maximum output of 30 W with a 4 mm tip catheter (group I; 47) or 40 W with an 8 mm tip catheter (group II; 61). Only in the group II patients were additional radiofrequency deliveries to the specific sites where the ECs tended to recover performed after successful SOCA. After the first procedure, PAF recurred in 47% of the group I patients and 32% of the group II patients. In all 27 patients who underwent repeat procedures, EC recoveries were observed more frequently in group I than in group II (69% versus 49%; P < 0.05). After multiple procedures, there was more freedom from PAF in group II (84%) than in group I (66%) (P < 0.05). SOCA with a higher RF power, larger tip catheter, and additional RF deliveries could achieve a more effective SOCA.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Catheter Ablation/standards , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/physiopathology , Catheter Ablation/instrumentation , Catheterization , Electrodes , Electrophysiology , Female , Follow-Up Studies , Heart/physiopathology , Humans , Male , Middle Aged , Recurrence , Stroke Volume
11.
Heart Rhythm ; 3(4): 377-84, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16567281

ABSTRACT

BACKGROUND: How extensive should an appropriate pulmonary vein (PV) ablation be is a matter of controversy. OBJECTIVE: The study's aim was to investigate the efficacy of minimally extensive PV ablation for isolating the PV antrum (PVA) with the guidance of electrophysiological parameters. METHODS: Fifty-five consecutive symptomatic paroxysmal atrial fibrillation (PAF) patients underwent PV mapping with a multielectrode basket catheter (MBC). A 31-mm MBC was deployed in 3-4 PVs as proximally as possible without dislodgement, and the longitudinal PV mapping enabled us to recognize single sharp potentials formed by the total fusion of the PV and left atrial potentials around the PV ostium or the transverse activation patterns that were observed. Those potentials were defined as PVA potentials. Radiofrequency ablation was performed circumferentially targeting PVA potentials with the end point being their elimination. RESULTS: After circumferential PVA ablation, electrical disconnection was achieved in 77% and residual PVA conduction gaps were observed in 23% of all targeted PVs. Those residual conduction gaps were mainly located at the border between ipsilateral PVs (42%) and between the left PVs and left atrial appendage (33%) and were eliminated by a mean of 3 +/- 2 minutes of local radiofrequency deliveries. During the follow-up period (11 +/- 5 months), 46 (84%) patients were free of symptomatic PAF without any anti-arrhythmic drugs. No PV stenosis or spontaneous left atrial flutter occurred. CONCLUSIONS: Electrophysiological PVA ablation with an MBC is feasible and effective for curing PAF because this minimally extensive PVA isolation technique targets the optimal sites, achieving both high efficacy and safety.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Electrophysiologic Techniques, Cardiac , Pulmonary Veins/physiopathology , Pulmonary Veins/surgery , Aged , Atrial Appendage/physiopathology , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Atrial Function, Left , Catheter Ablation/adverse effects , Electrodes, Implanted , Feasibility Studies , Female , Follow-Up Studies , Heart Conduction System/physiopathology , Heart Conduction System/surgery , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures , Research Design , Treatment Outcome
12.
J Interv Card Electrophysiol ; 12(1): 23-33, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15717149

ABSTRACT

INTRODUCTION: Pulmonary vein (PV) isolation (PVI) has been recently proposed as an effective technique to cure atrial fibrillation (AF). AIMS OF THE STUDY: The aim of this study was to investigate the efficacy of a novel technique utilizing a computerized three-dimensional mapping system (QMS2) with a multielectrode basket catheter (MBC) for PVI and to reveal the relation between the style of breakthrough and the network of the PV musculature. METHODS: Sixty-five consecutive patients with frequent AF attacks underwent PV mapping with a 31-mm MBC, and a three-dimensional color animation of the potential map was constructed by the QMS2. The animation color schema was arranged to minimize the low-amplitude left atrial (LA) potentials and emphasize the high-amplitude PV potentials (PVPs). The longitudinal PVP map enabled us to recognize the true breakthroughs and reveal the network of the PV musculature. RESULTS: A total of 205 PVs (65 left superior PVs, 65 right superior PVs, 57 left inferior PVs and 18 right inferior PVs) were mapped and successful PVI was achieved in all PVs, except one that had no PVPs, with a mean radiofrequency duration of 7 +/- 5 minutes per PV. In about 90% of the PVs, a final radiofrequency application eliminated all the distal PVPs simultaneously because the PVI was performed at the appropriate LA-PV junction. A single segmental breakthrough was detected in 17 PVs, single broad breakthrough in 83 PVs, multiple separate breakthroughs with a distal connection between the PV musculatures extending from each separate breakthrough in 88 PVs and multiple separate breakthroughs without that connection in 16 PVs. During the follow-up period, fifty-one (78%) patients were free of symptomatic AF without any antiarrhythmic drugs after multiple procedures (thirty-three (51%) of those patients after the first procedure) and no PV stenosis was found. CONCLUSIONS: Computerized three-dimensional potential mapping can be useful for PVI because it can not only identify the true breakthrough, but can also confirm the elimination of the breakthroughs by the change in the activation sequence through the network of the PV musculature.


Subject(s)
Atrial Fibrillation/surgery , Body Surface Potential Mapping/instrumentation , Heart Conduction System/physiopathology , Image Processing, Computer-Assisted/methods , Pulmonary Veins/surgery , Analysis of Variance , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Chi-Square Distribution , Echocardiography, Three-Dimensional , Female , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Ultrasonography, Interventional
13.
J Cardiovasc Electrophysiol ; 15(7): 745-51, 2004 Jul.
Article in English | MEDLINE | ID: mdl-15250855

ABSTRACT

INTRODUCTION: The right pulmonary veins (RPVs) and posterior wall of the right atrium (PRA) are anatomically located adjacent to each other. The aim of this study was to demonstrate the electrophysiologic characteristics of atrial tachycardia (AT) originating from the PRA or RPVs. METHODS AND RESULTS: A total of 26 consecutive patients with AT originating from the RPVs or PRA underwent detailed atrial endocardial mapping and successful radiofrequency catheter ablation. Eight foci were found in the PRA and 18 foci in the RPVs. Analysis of P wave configuration showed that lead V1 was the most helpful in distinguishing the AT foci between these two sites. In all cases, double potential (DP) configurations were recorded from several electrodes of a multielectrode catheter placed in the PRA, and the first DP component (FP) was the earliest potential recorded from the right atrium during the tachycardia. The amplitude of the FP was higher than that of the second DP component (SP) for AT foci originating in the PRA, whereas the reverse occurred for those in the RPV. The activation sequence of the FP was from superior to inferior for the AT foci in the superior RPV, whereas the reverse occurred for the AT foci in the inferior RPV. CONCLUSION: P wave configuration in lead V1 is helpful in distinguishing AT foci between those originating in the PRA and RPVs. The DPs obtained from the PRA can be useful in predicting whether AT foci originate from the PRA or RPVs.


Subject(s)
Electrocardiography , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Tachycardia, Ectopic Atrial/physiopathology , Adolescent , Adult , Aged , Catheter Ablation , Chi-Square Distribution , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Tachycardia, Ectopic Atrial/surgery
14.
Biomaterials ; 25(10): 1795-803, 2004 May.
Article in English | MEDLINE | ID: mdl-14738843

ABSTRACT

The long-term stability of bone tissues induced by recombinant human bone morphogenetic protein-2 (rhBMP-2) and poly[L-lactide-co-glycolide] copolymer-coated gelatin sponge (PGS) was examined. In 16 dogs, 2.5 cm unilateral bone defects were created in the left tibial diaphyses. Tibia was fixed with metal plate, and PGS impregnated with (0.4 mg/cm(3)) or without rhBMP-2 was implanted into 15 or one defects, respectively. The metal plates of rhBMP-2-treated limbs were removed 16 weeks after the implantation. The bilateral tibiae of five animals each of the rhBMP-2-treated group were harvested at 32, 52 or 104 weeks, and served for biomechanical testing and histology. Although the defect that received PGS alone resulted in nonunion at 16 weeks, all defects treated with rhBMP-2 achieved radiographic bony union by 8 weeks. Biomechanical properties of the regenerated bones restored to the levels of intact tibiae at 32 weeks, but torsional stiffness was significantly higher. No statistical significances were detected in all parameters between regenerated and intact tibiae at 104 weeks. No radiographic and histological findings suggesting enhanced resorption to the regenerated bones were observed. These results suggest the long-term stability of the bone tissues induced by rhBMP-2, and the usefulness of rhBMP-2-impregnated PGS as a biomaterial for long bone defect filling.


Subject(s)
Bone Morphogenetic Proteins/administration & dosage , Bone Regeneration/drug effects , Bone Transplantation/methods , Fracture Healing/physiology , Lactic Acid , Polyglycolic Acid , Polymers , Tibial Fractures/diagnosis , Tibial Fractures/therapy , Transforming Growth Factor beta , Animals , Biocompatible Materials , Biodegradation, Environmental , Bone Morphogenetic Protein 2 , Dogs , Drug Carriers/administration & dosage , Follow-Up Studies , Fracture Healing/drug effects , Male , Materials Testing , Polylactic Acid-Polyglycolic Acid Copolymer , Tensile Strength , Tibial Fractures/physiopathology
15.
Heart Rhythm ; 1(4): 427-34, 2004 Oct.
Article in English | MEDLINE | ID: mdl-15851195

ABSTRACT

OBJECTIVES: The purpose of this study was to investigate the efficacy of a novel catheter mapping technique for predicting atrial fibrillation (AF) foci. BACKGROUND: Most AF originates from pulmonary veins (PVs), but some originate from the right atrium. METHODS: We developed an algorithm by correlating the cardiac recordings obtained from multielectrode catheters placed in the posterior right atrium (RA) and esophagus during pacing from the PVs and superior vena cava (SVC) or crista terminalis (CT) in 10 AF patients. We tested the algorithm's accuracy prospectively in 46 AF patients. RESULTS: During pacing from the left PVs, the esophageal potentials preceded all other potentials. During pacing from both the right PVs and SVC-CT, the first component (FP) of the double potential (DP) recorded in the posterior RA preceded all other potentials. The amplitude of the FP was higher than that of the second DP component during pacing from the SVC-CT, whereas the reverse occurred from the right PVs. The activation sequence of the FPs and esophageal potentials was from superior to inferior during pacing from the superior PVs, whereas the reverse occurred from the inferior PVs. The accuracy of predicting 34 foci in the right PVs, 28 foci in left PVs, and 6 foci in SVC-CT was 100% for all, respectively. The accuracy of discriminating foci in the superior PVs from those in the inferior PVs was 97% in the right PVs and 96% in the left PVs. CONCLUSIONS: The technique using mapping catheters placed in the posterior RA and esophagus is feasible and effective for mapping and ablating AF.


Subject(s)
Atrial Fibrillation/physiopathology , Body Surface Potential Mapping/methods , Catheter Ablation , Heart Atria/physiopathology , Pulmonary Veins/physiopathology , Algorithms , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Prospective Studies
16.
Sarcoidosis Vasc Diffuse Lung Dis ; 20(2): 133-7, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12870723

ABSTRACT

BACKGROUND: The usefulness of corticosteroid therapy for cardiac sarcoidosis has not yet been fully clarified. METHODS: Of 40 patients diagnosed with cardiac sarcoidosis, twenty patients complicated by atrioventricular block but normal cardiac function (left ventricular ejection fraction > or = 50%) were divided retrospectively into one group (n = 7) receiving corticosteroids and another (n = 13) not receiving these agents. Over a mean observation period of 79.4 +/- 39.9 months, long-term outcome and laboratory findings were compared between the two groups and side effects also were noted. RESULTS: There were no deaths in the corticosteroid-treated group. In the untreated group, 2 patients died (15.4%). Atrioventricular block resolved in 4 of the 7 patients in the treated group (57.1%), but did not resolve or improve in any of the untreated patients (p < 0.05). Left ventricular ejection fraction did not differ significantly between the treated and untreated groups at the time of initial evaluation (66.7 +/- 6.5% vs. 60.5 +/- 6.4%). In the follow-up period, a marked decline in the ejection fraction had occurred in the untreated group (37.6 +/- 17.3%), but not in the treated group (62.1 +/- 4.4%; p < 0.005). Ventricular tachycardia was not present at the initial assessment in any patient in either group. In the follow-up period, ventricular tachycardia occurred in only 1 of 7 treated patients (14.3%), but was present in 8 of 13 untreated patients (61.5%; p < 0.05). However, side effects of corticosteroid therapy were noted in 6 of the 7 treated patients (85.7%). CONCLUSION: Our findings suggest that corticosteroids are useful in the treatment of cardiac sarcoidosis complicated by atrioventricular block but with normal cardiac function. However, these agents must be used with caution, with the maintenance dose kept as low as possible.


Subject(s)
Adrenal Cortex Hormones/pharmacology , Cardiomyopathies/complications , Cardiomyopathies/drug therapy , Heart Block/drug therapy , Sarcoidosis/complications , Sarcoidosis/drug therapy , Aged , Aged, 80 and over , Cardiomyopathies/pathology , Female , Heart Block/etiology , Humans , Male , Middle Aged , Retrospective Studies , Sarcoidosis/pathology , Stroke Volume , Treatment Outcome
17.
Circ J ; 67(6): 490-4, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12808264

ABSTRACT

It has been reported that some patients with acute myocarditis have transient ventricular thickening associated with narrowing of the left ventricular cavity caused by interstitial edema. The present study investigated this phenomenon in 20 patients with acute myocarditis. Based on the sum of the interventricular septal wall thickness and left ventricular posterior wall thickness (IVST + PWT), measured by M-mode echocardiography, patients were divided into group A (IVST + PWT >/=25 mm, n=12) and group B (IVST + PWT <25 mm, n=8). The IVST + PWT was 31.8 +/-3.5 mm in group A and 21.9+/-2.7 mm in group B (p<0.0001). The left ventricular end-diastolic dimension (LVDd) was 42.3+/-6.0 mm in group A and 49.4+/-6.7 mm in group B (p<0.05). The stroke volume (SV) was 41.1+/-20.5 ml and 73.0+/-32.3 ml in groups A and B, respectively (p<0.05). The left ventricular ejection fraction (LVEF) was similar in group A (47.9+/-13.0%) and group B (56.9+/-9.0%). The SV correlated inversely with IVST + PWT (r=-0.62, p<0.01), and directly with both the LVDd (r=0.95, p<0.0001) and LVEF (r=0.64, p<0.01). The LVDd correlated inversely with IVST + PWT (r=-0.62, p<0.01). In conclusion, the reduction in SV that occurs during the acute phase of myocarditis is not only the result of systolic dysfunction, but also of the concentric left ventricular wall thickening associated with myocardial interstitial edema, which results in narrowing of the left ventricular cavity at end diastole.


Subject(s)
Heart Ventricles/pathology , Myocarditis/physiopathology , Myocardium/pathology , Stroke Volume , Ventricular Dysfunction, Left/physiopathology , Acute Disease , Adolescent , Adult , Aged , Child , Convalescence , Diastole , Edema/etiology , Female , Heart Septum/pathology , Heart Ventricles/diagnostic imaging , Humans , Male , Middle Aged , Myocarditis/complications , Myocarditis/diagnostic imaging , Myocarditis/pathology , Retrospective Studies , Ultrasonography , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/pathology
18.
J Cardiol ; 40(1): 31-5, 2002 Jul.
Article in Japanese | MEDLINE | ID: mdl-12166247

ABSTRACT

A 54-year-old woman with an implantable cardioverter-defibrillator was admitted because of convulsion. Previously, she had suffered methicillin-resistant Staphylococcus aureus (MRSA) sepsis induced by a central venous catheter. Despite removal of the central venous catheter and administration of vancomycin, fever and increased C-reactive protein level persisted. MRSA had probably infected the implantable cardioverter-defibrillator system. Gallium scintigraphy showed accumulation at the right subclaviculan area, although local inflammatory signs were absent. Intravascular ultrasonography demonstrated intravenous vegetation at the bifurcation of the right subclavian vein and right internal jugular vein. Antibiotic therapy was not curative, so she underwent extirpation of the intravenous vegetation, which cured the systemic inflammation. Intravascular ultrasonography was useful to differentiate central venous catheter-related infection from implantable cardioverter defibrillator-related infection.


Subject(s)
Catheterization, Central Venous/adverse effects , Defibrillators, Implantable , Methicillin Resistance , Staphylococcal Infections/etiology , Staphylococcus aureus , Device Removal , Female , Humans , Jugular Veins/diagnostic imaging , Jugular Veins/pathology , Middle Aged , Subclavian Vein/diagnostic imaging , Subclavian Vein/pathology , Ultrasonography, Interventional
19.
J Cardiovasc Electrophysiol ; 13(4): 324-30, 2002 Apr.
Article in English | MEDLINE | ID: mdl-12033346

ABSTRACT

INTRODUCTION: Transient T wave changes after cessation of preexcitation have been attributed to cardiac memory. However, there have been no reports on the effects of long-term cardiac memory on repolarization dispersion before and after catheter ablation in patients with Wolff-Parkinson-White (WPW) syndrome. METHODS AND RESULTS: We investigated 47 patients with an accessory pathway (AP; 24 manifest left-sided, 14 manifest right-sided, and 9 concealed left-sided). Repolarization dispersion was analyzed by two methods, recovery time (RT) dispersion and newly proposed T wave width (WT), from 87-lead body surface maps before, 1 day after, and 7 days after catheter ablation. RT dispersion and WT were significantly correlated before, 1 day after, and 7 days after catheter ablation (r = 0.78). In patients with preexcitation, RT dispersion and WT increased significantly (P < 0.05) 1 day after catheter ablation (178 +/- 32 msec and 172 +/- 30 msec) compared with those before (154 +/- 24 msec and 156 +/- 18 msec) and 7 days after catheter ablation (147 +/- 19 msec and 156 +/- 16 msec), respectively. However, there were no significant changes in RT dispersion and WT before and after catheter ablation in concealed WPW syndrome. CONCLUSION: The findings suggest that the abrupt changes in activation sequence increase repolarization dispersion in the presence of previous cardiac memory, and that the dispersion decreases days or weeks after alteration of activation sequence by catheter ablation, with development of new cardiac memory in patients with manifest WPW syndrome.


Subject(s)
Body Surface Potential Mapping/methods , Heart Conduction System/physiopathology , Heart/physiopathology , Wolff-Parkinson-White Syndrome/diagnosis , Wolff-Parkinson-White Syndrome/physiopathology , Adaptation, Physiological , Adult , Aged , Catheter Ablation , Electrophysiology , Female , Humans , Male , Membrane Potentials , Middle Aged , Myocardial Contraction , Reproducibility of Results , Sensitivity and Specificity , Wolff-Parkinson-White Syndrome/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...